Products and prices: Precast concrete buildings for storage, hazard materials, restrooms, pump and equipment housing. Standard 10′ x 12′ x 8′ I.D., from $8,900 +/-. Standard 12′ x 20′ x 8′ I.D., from $12,000 +/-. Standard Hazmat, from $14,000 +/-. Outback Vault Restrooms: Blueridge, from $10,00 +/-, Double Sierra, from $25,000 +/-.

Plumbed or waterless: Buildings can be adapted to meet a variety of site conditions with or without public sewer and water connections.

Pre-plumbed and pre-wired: Buildings are available to customer-supplied specification as to interior finish and fit out. Buildings available as a shell or turnkey ready to use.

Type of toilets — vault, composting or flush: Buildings are available to customer-supplied specification as to interior finish and fit out using vault, composting or flush-style fixtures and accessories. Easi-Set buildings available as a shell or turnkey ready to use. OutBack vault restrooms use Fresh Air Naturally (FAN) technology.

Structure materials: Pre-cast concrete, 5,000 psi.

Vandalism & graffiti resistance features: Bullet tested to UL 752, Level 4 (30 caliber rifle fired at 15′), 5,000 psi steel reinforced concrete. No-maintenance exterior finishes available. Tamper-proof hinges, dead bolt locks and steel doors.

Pre-fabricated or assembled on-site: Easi-Set buildings are easily transported and installed. Standard models are delivered pre-assembled and field installation on larger custom sizes. Installation is in hours instead of weeks.

ADA-compliance features: Meets Accessibility Guidelines for Buildings & Facilities (ADAAG), California Accessibility Regulations, Title 24, and the Uniform Federal Accessibility Standards (UFAS).

Single, double, multi-user: Easi-Set buildings are available as single, double, multi-user units or in any combination needed. Units can be installed as modular units.

Restroom-only, showers or multi-use: Easi-Set buildings are available as restroom only as single, double, multi-user units with or without showers with press boxes, concessions, and storage combined as needed.

Environmental considerations: Saves time with less impact to surrounding environment, re-locatable; can be moved as needs change. Weather-tight features include turned down roof to prevent moisture penetration, above door rain-guard for drip protection, galvanized door and frame with specially reinforced mechanical hold open arm, step-down floor for additional water-tight integrity, raised aluminum threshold with integral neoprene seal provides moisture, dust, and pest resistance, unique radial post-tension design for superior weather-tight construction, roof load capacity of 60 PSF with higher loads available, floor load 250 PSF standard, sloped roof panels with architectural ribbed edge. Meets BOCA, SBC, UBC, ICBO, UL, ANSI, ACI, and IBC 2003 requirements. Seismic Zone 4 rating and hurricane resistant up to 130 mph winds loading standard. Easi-Set buildings are fire resistant of 1.5 hours with additional protection available.

Site requirements: No foundations or footings are required. A level four-inch layer of sand or crushed stone on an approved sub-grade is all the preparation needed. Installation can be completed within a few hours.

Options: Unlimited optional features; the Easi-Set building can be shipped equipped for all applications.Optional sizes available up to 40′ wide by 150′ with interior heights of 12′.

Warranty policy: One year on materials and workmanship.

Design/engineering services offered: Custom designs are available through the Easi-Set Engineering Department.

Contact information: Easi-Set Industries, P.O. Box 300, 5119 Catlett Road, Midland, VA 22728, (540) 439-8911, (540) 439-1232 (fax), info@easiset.comThis e-mail address is being protected from spambots. You need JavaScript enabled to view it , www.easiset.com

J.F. Fitzpatrick Industries Inc.

Products: A variety of pre-fabricated restrooms and toilet/shower room combinations.

Pre-plumbed and pre-wired: Units with flush toilets, urinals and sinks are all pre-plumbed. Units with lighting packages or electrical heat are all pre-wired.

Type of toilets — vault, composting or flush: All types available.

Structure materials: Variety of materials, from wood, steel, fiberglass, cement board, cedar and bricks.

Vandalism & graffiti resistance features: All units are vandal and graffiti resistant.

Pre-fabricated or assembled on-site: Pre-fabricated in the factory, and depending on the unit and the amenities required, there may be some assembly on-site.

ADA-compliance features: Restrooms are ADA-compliant.

Single, double, multi-user: All.

Restroom-only, showers or multi-use: All types, including restroom/concession combos.